Login

Please fill your login details to rate.

E-Mail:


Password:

Forgot Password?

SEKONIC Flashmate (L308S)

Product Code: SFL308S
`17,000
Selling Price: `17,990
You Save: `990
Price includes all taxes.
Out of Stock
  • Free Shipping ( 1-2 BUSINESS DAYS )
  • Key Features
    • Incident or reflected light measurement
    • Ambient / Flash measurement
    • Accurate measurements
    • Compact size and lightweight
    • Description
    • Specifications
    • Features

    The pocket-sized Sekonic L-308S Flashmate is the smallest and lightest digital light meter in the Sekonic line-up. It is designed to read ambient or flash exposures in either reflected or incident modes, and it displays accurate exposure readings in full, half, or third-stop increments to mirror the exposure settings of today's DSLR and film cameras.

    The L-308S delivers accurate exposure readings in full-, half-, or third-stop increments to mirror the exposure displays of most popular cameras. When set to full-stop mode, exposures are displayed in tenth-stop increments with a repeat accuracy of +/- 0.1 EV.

    The LCD screen is designed to emulate the look and feel of its bigger brother, the Sekonic L-358 flash meter. Exposure data and related information are displayed using large type and easy-to-read icons, perfectly legible in even low-level lighting conditions.

    L-308S Flashmate - Technical Specifications

     Type  Digital exposure meter for ambient and flash light
     Receptor Head  Sliding Lumisphere with Lumidisc Adapter
     Light Receiving Method  Incident light and reflected light
     Receptor Incident Light  Built-In Lumisphere, Attachable Lumidisc (included)
     Receptor Reflected Light  Lens with 40° Receiving Angle
     Light Receptor Element  Silicone photo diode


    Measuring Range and Modes

     Measuring Modes Flash  Without synchro cord
     With synchro cord
     Measuring Range (ISO 100) Ambient Light  Incident light EV 0 to EV 19.9
     Reflected light EV 0 to EV 19.9 (with 40° angle)
     Measuring Range (ISO 100) Flash  Incident light f/1.4 to f/90.9 (approx. f/124)
     Reflected light f/1.4 to f/90.9 (approx. f/124) with 40° Lumigrid
     Repeatability Repeat Accuracy  (+/-) 0.1 EV or less
     Calibration Constant Incident  Lumisphere C = 340, Lumidisc C = 250
     Calibration Constant Reflected  K = 12.5


    Display Range and Modes

     Display Range Film Speed  ISO 3 to 8000 (in 1/3 steps)
     Display Range Shutter Speeds Ambient  60 sec to 1/8000 sec. (in 1, 1/2, 1/3 steps)
     Display Range Shutter Speeds Flash  1 sec to 1/500 sec. (in 1/ 1/2, 1/3 steps) plus 1/75, 1/80, 1/90, 1/100 sec.
     Display Range Aperture  f/0.5 to f/90.9 (in 1, 1/2, 1/3 steps)
     Display Range EV  EV -5.0 to EV 26.0 (in 1/10 steps)
     Display Cine Speeds fps  8, 12, 16, 18, 24, 25, 30, 32, 64, 128 (shutter angle: 180°)


    Other

     Exposure Out Of Range  Eu (underexposure) or Eo (overexposure)
     Auto Power Off  Yes, About 4 minutes after last usage
     Battery Power Indicator Display  Icon with 3 status
     Battery(Power)  (1) Type AA 1.5V Battery alkaline, manganese or lithium
     Operating Temperature Range  32° to 104° F / 0° to 40° C
     Storage Temperature Range  -4° to 140° F / -20° to 60° C


    Dimension and Weight

     Product Dimensions  4.30x2.50x0.90 in./10.90x6.40x2.30 cm
     Product Weight  0.20lbs./0.10kg.
    Incident or reflected light measurement
    Reflected light readings are captured at a receiving angle of about 40 degrees for subject readings made at the camera. Slide the L-308S's built-in Lumisphere over the silicon photo diode for incident light exposure readings of three-dimensional subjects. Snap on the included Lumidisc over the sensor for metering flat artwork or measuring contrast and/or exposure ratios within a scene.

    Ambient / Flash measurement
    Incident or reflected ambient light readings can be made with the L-308S over a wide range of lighting conditions at shutter speeds from 60 seconds to 1/8000th of a second and apertures from f/stops of f/1.4 to f/90.9. Flash at speeds from 1 to 1/500th of a second can be measured cordlessly or wired using a separate accessory PC cord. Flash and ambient readings are automatically calculated to display the proper exposure for the combination.

    Accurate measurements
    Exposures accurate down to a tenth-of-a-stop for both ambient and electronic flash light readings are available in full-stop mode. The L-308S can also display shutter speeds and apertures in half or third-stop increments to mirror the exposure settings on your camera with a repeat accuracy of +/- 0.1 EV. For cinema applications frame rates can be set from 8 to 128 frames per second. ISO sensitivity can be set from 3 to 8000 in third-stop increments.

    Compact size and lightweight
    The L-308S is the smallest digital flash meter for reflective and incident light readings in ambient or electronic flash lighting conditions. It is compact and light enough to fit into a shirt pocket, yet versatile enough to meet virtually every photographic demand. The L-308S is powered by a single AA battery and weighs only 3.4 ounces (95g). Its measurements are a compact 2.5"W x 4.3"H x 0.9"D (63mmW x 110mmH x 22mmD).